Release Notes

Product: PR01-0808
Description: Precis 8x8 4K60 HDMI Matrix Switcher
FG#: FG1020-800

File Name: SW1020-800_PR01-0808_v1_42_0
Firmware Version: 1.42.0
Release Date: 2020-12-16

!! Please read Programming Information for successful upgrade steps!!

1. Prerequisites
2. Features added in this release
3. Fixes in this release:
4. Known Issues
5. Programming Information
6. Notable Points


----------------------------------------------------------
1. Prerequisites
----------------------------------------------------------
- NetLinx Studio v4.3.1519 (or later)

----------------------------------------------------------
2. Features added in this release:
----------------------------------------------------------
- Added RS232 switching control (see manual for API commands)

----------------------------------------------------------
3. Fixes in this release:
----------------------------------------------------------
- Fixed issue causing continual "Custom Event Type 1009" notifications

----------------------------------------------------------
4. Known Issues
----------------------------------------------------------
- None

----------------------------------------------------------
5. Programming Information
----------------------------------------------------------
- These devices can be updated using a VNM (Virtual NetLinx Controller)
  but the update will go much faster if you can connect to a physical
  NetLinx controller.  VNM update could take up to 2 hours but
  using a physical controller should take less than an hour.

- The update takes place in 3 stages.  The first part of the update
  happens during the Firmware Transfer in NetLinx Studio.  Once that
  transfer has completed the device will then continue the update and 
  show its progress in the Update Status page of the devices webgui.
  This must be selected prior to update and then it can be monitored.
  Once that update shows as completed the unit will then display the
  last stage of the update on a display connected to the HDMI output.
  The device will reboot when it has completed the full update.

----------------------------------------------------------
6. Notable Points
----------------------------------------------------------
- These units have a web interface that is accessible by entering
  the IP of the device into a web browser.  This may indicate there
  is a certificate error, but you can select the Advanced option at 
  the bottom and proceed to the page.  A new certificate can be loaded
  via the web interface.