Release Notes

DXLink HDMI Transmitter Module Firmware 
(Enova DGX 100 Series Compatible)

!!IMPORTANT:  READ PROGRAMMING INFORMATION SECTION BELOW 
IN REGARD TO UPGRADING OLDER FIRMWARE VERSIONS!!

!!This firmware version requires Enova DGX 100 Series 
compatibility on connected Enova DGX systems!!

!!!Please reference the Enova DGX Board and Endpoint 
Compatibility Instructions on the AMX.com product 
page for more information!!!

FG#:
  FG1010-300    (AVB-TX-HDMI-DXLINK, DXLink HDMI Transmitter Module)
  FG1010-310    (DX-TX, DXLink Multi-Format Transmitter Module)
  FG1010-320-BL (DX-WP, DXLink Multi-Format Wallplate Transmitter)
  FG1010-320-WH (DX-WP, DXLink Multi-Format Wallplate Transmitter)
  FG1010-325-BL (DX-DWP, DXLink Multi-Format Decor Style Wallplate Transmitter)
  FG1010-325-WH (DX-DWP, DXLink Multi-Format Decor Style Wallplate Transmitter)

Release Date: 8/12/2016
Current Released Firmware: v1.8.28
SW1010_3XX_AVB_KIT_DXLINK_TX_v1_8_28.kit


----------------------------------------------------------
Table of Contents
----------------------------------------------------------

1. Prerequisites
2. Features added in this release
3. Fixes in this release
4. Notable Points
5. Programming Information

----------------------------------------------------------
1. Prerequisites
----------------------------------------------------------

- DXLink TX v1.6.7 (or later) must be loaded on the DXLink 
  Transmitters to upgrade

- DXLink RX v1.13.28 (or later) must be used on the DXLink 
  Receiver for best performance with this TX version

- Enova DGX 800/1600/3200/6400 must have v3.2.4 (or later)
  to allow use of the new ICSLAN feature and async status
  improvements in this release. Else v3.0.20 (or later)
  The DGX 100 Series Master FW should be:

    - SW2106_NX-X200_Master_v1_4_86.kit(or later)

- Enova DGX 8/16/32/64 enclosures need Enova DGX 8/16/32/64
  FW v2.2.8 (or later) and Master FW:

    - SW1056_Master_v4_2_395.KIT (NI-Series) Shows in Online
      Tree as "NI Master"

    - SW2106_NX-X200_Master_v1_3_106.kit (NX-Series) Shows
      in Online Tree as "DGX Master"

- NetLinx Studio v4.3.1519

- DGX Configuration Software v1.0.6 or later

----------------------------------------------------------
2. Features added in this release
----------------------------------------------------------

- Added ability to set TX ICSLAN port to be on the public
  or private network. Added new DGX ICSP command:
  5002:x:0 ENDPOINT_TX_ICSLAN_PORT-<PRIVATE|PUBLIC>
  Where x is the input channel connected to the TX.
  !!NOTE: This requires DGX v3.2.4 (or later)!!

----------------------------------------------------------
3. Fixes in this release
----------------------------------------------------------

Fixed random offline/online events.

== Previously released in v1.8.26 ==========================

- Fixed issue where WP/DWP don't come online in AutoSetup 

- Fixed video flicker issue caused by certain cameras or 
  other DVI sources

- Improved audio/video detection with difficult sources

- Fixed colorspace and video/audio detection issues when
  connected to a DXLink 4K Input card

- Fixed IR TX LED issue and IR one way serial reliability

- Fixed instances where the MFTX status (via ICSP or Web
  Interface) could get out of sync

- Corrected some differences in status reporting (compared
  to other TX products) when no signal is present

----------------------------------------------------------
4. Notable Points
----------------------------------------------------------

- PLEASE READ the documentation in regard to the DIP 
  switches located on the bottom of the Tx/Rx modules 
  before attempting to connect to the network

- After a FACTORYAV (ICSP) or RESET FACTORY (telnet)
  command, a reboot of the endpoint is required.

----------------------------------------------------------
5. Programming Information
----------------------------------------------------------
!!This firmware version requires Enova DGX 100 Series 
compatibility on connected Enova DGX systems!!

- !!!Please reference the Enova DGX Board and Endpoint 
  Compatibility Instructions on the AMX.com product 
  page for more information!!!

--UPGRADING-----------------------------------------------
!! ImportantTwo loads of this kit MAY be required if   !!
!! upgrading from firmware earlier than v1.6.7          !!
!!                                                      !!
!! 1. Transfer kit v1.8.28 to the TX. If upgrading from !!
!!    a version earlier than 1.6.7, it will abort due to!!
!!    a memory error.  If so, proceed to step 2         !!
!!                                                      !!
!! 2. Reboot the TX (via telnet or power cycle) then    !!
!!    check the firmware versions in the Online Tree:   !!
!!                                                      !!
!!eg. 32002 - DXLINK-HDMI-MFTX-v1.8.28                  !!
!!      [OID=1] - MQX (v3.62)                           !!
!!      [OID=2] - DXLINK Boot (v1.8.28)                 !!
!!      [OID=3] - DXLINK App (v1.8.28)                  !!
!!      [OID=5] - DXLINK Link (3.0.6.0)                 !!
!!                                                      !!
!! 3. If the Link version is still not up to date, then !!
!!    transfer v1.8.28 again to completele the update of!!
!!    the final component. If the FW is up to date then !!
!!    no other kit transfers are required.              !!
==========================================================

 
- PLEASE reference Appendix A (Upgrading the Firmware) in the 
  DXLink Instruction Manual for more information.