Necessary tools:
NetLinx Studio 2 (NS2)
USB cable (if downloading via USB)
Network connection information (if downloading via ethernet)

Necessary files:
SW2262-01-KIT  (SW2262-01_v2.86.6.zip)



1) Extract the zip file
2) It should produce five kit files; "SW2262-01_v2.4prep.kit", "SW2262-01_v2.4.6.kit", 
   "SW2262_01_NXD430_v2_4_9.kit", "SW2262-01_NXD430_v2_4_27.kit"and "SW2262-01_NXD430_v2_86_6.kit"

Version 2.4.27 is not used in this upgrade process but is included in case users want to revert
to the previous release.


To upgrade from version prior to v2.4.6

1) Boot the NXD-430 and configure a connection to NS2.  Verify the connection with NS2.
2) Ensure that the reboot device button is checked on the Send to NetLinx Device firmware transfer page.
3) Begin the upgrade by downloading the "SW2262-01_v2.4prep.kit" to the panel.  It may be
   necessary to wait up to 5 minutes after the panel reboots for the upgrade process to complete. This
   prepares the panel to maintain two sets of setup pages (portrait and landscape).
4) After the upgrade is completed and a master connection is re-established, download the
   "SW2262-01_v2.4.6.kit" to the panel.
5) After the upgrade is completed and a master connection is re-established, download the
   "SW2262_01_NXD430_v2_4_9.kit" to the panel.
6) After the upgrade is completed and a master connection is re-established, download the
   "SW2262_01_NXD430_v2_86_6.kit" to the panel.
7) Verify the panel is upgraded to v2.86.6

To upgrade from version v2.4.6 or later but before v2.4.9

1) Boot the NXD-430 and configure a connection to NS2.  Verify the connection with NS2.
2) Ensure that the reboot device button is checked on the Send to NetLinx Device firmware transfer page.
3) Begin the upgrade by downloading the "SW2262_01_NXD430_v2_4_9.kit" to the panel.
4) After the upgrade is completed and a master connection is re-established, download the
   "SW2262_01_NXD430_v2_86_6.kit" to the panel.
5) Verify the panel is upgraded to v2.86.6


To upgrade from version v2.4.9 or later

1) Boot the NXD-430 and configure a connection to NS2.  Verify the connection with NS2.
2) Ensure that the reboot device button is checked on the Send to NetLinx Device firmware transfer page.
3) Begin the upgrade by downloading the "SW2262_01_NXD430_v2_86_6.kit" to the panel.
4) Verify the panel is upgraded to v2.86.6