The Soundweb London BLU-32 Signal Processor offers configurable I/O and CobraNet audio. The processor features CobraNet audio with primary and secondary ports for fault tolerance. Control is accomplished via a separate Ethernet port which allows CobraNet and control networks to be easily separated or mixed depending upon requirements.
Four card slots which accommodate analog inputs, analog outputs, digital inputs and digital outputs in banks of four facilitate many different device I/O configurations. Analog Input Cards provide software configurable gain in 6dB steps up to +48dB per channel and software selectable Phantom Power per channel. Digital Input Cards and Digital Output Cards process AES/EBU and/or S/PDIF audio and offer a variety of clocking and syncing options. (Further information about the I/O cards can be found on dedicated datasheets) Phantom Power, Sync, Signal Present and Clip information per channel is easily accessible, without the requirement for a PC, from clear front panel LED indication. Device-specific information such as Device Name, Device Type, Firmware Version Number, Time, IP Address and Subnet Mask is available from the front panel display. A bi-directional locate function allows devices to be identified both from and within HiQnet Audio Architect. 12 Control Inputs and 6 Logic Outputs allow the BLU-32 to be integrated with GPIO compatible devices. The BLU-32 and the other members of the Soundweb London family provide the building blocks of the perfectly tailored system solution.
Name: The name of this item
Class Name: The type of this device
Device ID: The ID number of this device
Acknowledge (ACK): Set to 'yes' to inform the London device that is should expect acknowledgement of the messages being sent.
Baud Rate: Drop-down selection for the Baud Rate
Data Bits: The number of bits for data
Parity: The parity
Stop Bits: The number of stop bits
Dynamic Meters: The number of Dynamic Meters to use in this device. Hover the cursor over a wire in the design while online and a Dynamic Meter displays the signal level.
Logic Change Block: If enabled, only Logic Sources and Ends will be written to the change block. Only enable if there are performance issues with logic.
Logic Subscription: If enabled, only Logic Sources and Ends will be subscribed to. Only enable if there are issues with logic.
Recall Presets on Startup: When enabled, presets assigned to control ports will be recalled when the device is powered on.
Control Port Subscribe: When enabled, force control ports to subscribe to controlled parameters.
Sample Rate Pulldown: Sample rate pulldown frequency when an external sync source is being used
Four Input / Output Card Slots
Configurable Inputs / Outputs
Analog Inputs (with Phantom Power per Channel)
Analog Outputs
Digital Inputs (AES/EBU and S/PDIF)
Digital Outputs (AES/EBU and S/PDIF)
Rich Palette of Logic Objects
CobraNet Audio
Clear Front Panel LED Indication
Informative Front Panel Display
Bi-Directional Locate Functionality
12 Control Inputs and 6 Logic Outputs for GPIO Integration
HiQnet Device
Custom I/O (card based) |
Yes |
Analog Inputs |
Up to 16 |
Digital Inputs |
Up to 16 |
Analog Outputs |
Up to 16 |
Digital Outputs |
Up to 16 |
Max Inputs/Outputs |
16 |
Logic Processing |
Yes |
RS-232 |
Yes |
GPIO |
Yes |
Signal Processing |
Yes - 200 MHz |
Cobranet |
No |