Individual Device Monitor Panel
JBL DrivePack®

Overview

The Individual Monitor Panel displays status panels of all the devices selected from the venue as individual monitor panels.  All control and monitor functions are parallel to the associated controls in the device GUI.   The master frame has the ability to display up to eighteen individual devices before adding in a scroll bar to view devices not see in the visible window.  Each panel includes all the controls of the Overall JBL Master Monitor Panel and also includes a locate button and shows the individual devices’ gain. Each device shows its HiQnet address and name. 

Features

Controls

For details on any individual control see help for Input Control and Monitor Sub-Panels

Monitor Display Panel

For details on any individual display see help for Input Control and Monitor Sub-Panels

      • Green; Not Muted – Mute indicator reads "Mute" when the input section is active (not muted).
      •  
      • Red; Muted – Mute indicator reads "Muted" when the input section is inactive (muted).
      • Green - Normal
      • Yellow - Internal limiters for the associated input or output is engaged.
      • Red  - Internal limiters are in advanced stages of limiting.
      • Green - Device is within normal operating conditions.
      • Yellow -Temperature of the device within the first stage of thermal limiting.
      • Red - Temperature of the device is in advanced stages of thermal limiting and within the thermal shutdown temperature range.  Action should be taken immediately to correct the situation. 
      • Green – Loudspeaker load is within defined normal range.
      • Yellow - Loudspeaker load is above defined normal range, open circuit.