Master Panel Input Routing 


Input Routing functionality on JBL Master Panels is the same as in individual JBL Device control panels.

Input Routing JBL DPAN devices
Input Routing JBL DPCN devices
Input Routing JBL DPDA devices

Double Clicking in the index box of any  level control will open a  pop-up Master Individual Device Control Sub-Panel

   

The Input Routing Panel on the left is from a DPAN-only JBL Master Panel.
The Input Routing Panel on the right is from a JBL DPCN or mixed DPAN/DPCN master control panel.

Changes made in the Master Routing Panel effect the change in all devices in the group.  Level controls are soft linked.  See help on Gain Offsets for more information.

CobraNet Input & Source Control

Selections made in the CobraNet control Sub -Panel are global and force the values selected in the Bundle, Slot and Source Select fields to all DPCN devices.

Mute and Polarity are hard link controls and force all devices in the group to the selected state. 

The visible fields will display the settings from the first device added to the Master Panel as these values will typically be the same in all devices in the group.  Any of these values can be edited in individual devices. 


If any values in a device are different from the group, an alert will appear on the parameter that is not the same across all devices in the group.