Meter Gradient

A gradient meter is an output meter that shows the state of a device parameter in specifically designed gradients.

Controls can be managed in the Custom Panel designer and, once the Custom Panel is activated, utilized by the end user. This control must be linked to a parameter to function properly.

Properties

 

OPTIONS / INSTRUCTIONS

NOTES / EXAMPLE

General

 

 

Control Info

Shows control type

Read only

Locked

Specifies if the control is locked out so that it cannot be moved or re-sized

Checked = Locked

Unchecked = Unlocked

Parameters

Peak Equation

When specified, this equation combines the attached parameter's values and returns the peak that the control will display

Choose from drop down list

Addresses

The HiQnet address of the control

Enables panel designer to edit addressing information with the added benefit that the values can be validated as a group before being applied to the device.

This editor also allows the user to assign multiple parameters to the control.

Click to select Parameter Address Editor:

Properties correspond to the system explorer

Information

Shows information about the Parameter Address

Read only

Properties correspond to the system explorer

Maximum The maximum deployable value for the meter  

Minimum

The maximum deployable value for the meter

 

Value Equation

When specified, this equation combines the attached parameter's values and returns the value that the control will display

 

Gain Reduction

Check if this meter is to be a Gain Reduction style. The negative dB gains are reported (shown) as increasing positive gains

 

Appearance

Optimized for Speed

Enables the meter to draw faster. Note:This decreases the aesthetic properties of the meter

 

Location

Control location (in pixels) of the control on the Custom Panel

Change X (horizontal) and Y (vertical) values in relation to upper left corner

You can also drag the control to a different location

 

Size

Control size (in pixels)

Change width and height values

You can also re-size the control manually

 

Tool Tip Text

Text that appears on control mouse-over

 

Tab Index

Indicates the sequence of an element within the tabbing order of all focusable elements in the document.

 

Tab Stop

Whether the control appears in the tab order

Checked = Appears

Unchecked = Won't appear

Meter

Orientation

The orientation of the meter; Vertical or Horizontal

Select Left to Right, Right to Left, Top to Bottom, or Bottom to Top

High Color

The color of the upper section of the meter

Brings up the Select Color window

 

Mid Color

The color of the mid section of the meter

Brings up the Select Color window

 

Low Color

The color of the lower section of the meter

Brings up the Select Color window

 

High Threshold

The value at which the upper section ends and the mid section begins

 

Mid Threshold

The value at which the mid section ends and the lower section begins

 

Peak Color

The color of the peak line

Brings up the Select Color window

 

Gradient Fraction

Determines which portion of a meter section is gradient filled

 

Draw Peak

If checked, the peak line will be displayed

 

Peak Thickness

The thickness, in pixels of the Peak Line

 

Peak Decay Rate

Percent of the meter that the Peak Line will drop per second

 

Border Style

The border style drawn around the meter

Select from drop down list

Background Color 1

First background color used in the gradient behind the meter itself

Brings up the Select Color window

 

Background Color 2

Second background color used in the gradient behind the meter itself

Brings up the Select Color window

 

Scale

Display Scale

When checked, the scale is enabled

 

Font

Click on "..." to select desired font. Brings up a Font Select window

Selects from Windows fonts

Background Color

The background color for the scale

Brings up the Select Color window

 

Fore Color

The foreground color for the scale

Brings up the Select Color window

 

Scale Location

Placement for the scale (the scale must be enabled first)

Right or Bottom, Left or Top

Custom Ticks

Customized ticks for the control. Parameters must be set first  

Scale Count

The number of scale entries to display

 

Scale Space

Space to allocate for the scale